Model A, Anti-Syphon Valves - Installed in a vertical position at the highest point in the suction line with no part of the line between the valve and the tank below the maximum oil storage level. UL listed; Approved by the New York City Board of Standards and Appeals. Preferred Utilities' industrial factory is located in Danbury, CT (Connecticut).
Model BQ, Back Pressure Regulating Valves - Maintain constant supply pressure for generators, boilers, booster pumps, or any other application that requires constant oil pressure.
Model V, Back Pressure Regulating Valve - Installed at the far end of the oil supply line, down stream of the boiler fuel metering valves and passes unburned oil to the return line.
Rugged, maintenance-free terminal protection for breather lines from sumps, reservoirs, expansion tanks and a wide assortment of industrial applications. Preferred Utilities' industrial factory is located in Danbury, CT (Connecticut).
Model 72, Duplex Oil Strainers - For duplex fuel oil handling systems and for those applications where the requirement for a continuous supply of oil does not permit interruption of the flow for the routine cleaning of strainer baskets.
Model 110-G, Fire Safety Gas Shut-off Valves - Used in any gas flow application by locating the valve in a horizontal pipe run where the gas supply enters the building.
Model 233-FV, Foot Valve Extractor Fitting - Permits easy removal and reinstallation of the Model 22 Double Poppet Foot Valves or Model 900 Single Poppet Foot Valves sizes smaller than 1½".
Model DT, Fuel Oil Day Tanks - Provide a local supply of distillate or diesel fuel for boilers, emergency generators or other stationary engine driven or oil fired equipment. Available from 20 to 620 gallon capacities, a properly sized tank may be selected per individual job. Diesel or #6 Oil. Stored in our factory, Danbury, CT (Connecticut).
Fusomatic Electric Cut-Off Switch - The Fusomatic Electric Cut-Off Switch is a thermally actuated safety switch used in combustion installations. As required by many codes, it automatically breaks the burner control circuit in the event of a fire. Approved by The Massachusetts Department of Public Safety and Underwriters Laboratories Inc.
Fusomatic Globe / Gate Valve - Thermally actuated safety switch used in combustion installations. As required by many codes, it automatically breaks the burner control circuit in the event of a fire. Approved by The Massachusetts Department of Public Safety
Model 1, Ground Level Spill Containers - Designed to catch any oil which can be spilled when disconnecting the delivery fitting during normal tank filling operations.
Model 110, Spring Loaded Fire Safety Valves - Used in fuel oil piping systems to provide automatic shut-off of the fuel flow in the event of a fire. Valve operation is fully mechanical and is independent of the electrical power supply. The emergency fuel line shut-off is mandated by many codes.
Bi Metal Oil Thermometer - White dial with highly visible black numbers and pointer. The case is of welded stainless steel construction and is hermetically sealed to prevent the entrance of damaging moisture.
Model 71 & Model 61F-Stop, Overfill Prevention Valves - Provides a mechanical method of automatic fuel oil shut-off to prevent overfilling of underground storage tanks during a gravity filled delivery. It is designed to satisfy EPA regulations covering overfill protection, “a device that will automatically shut off the flow of oil into the tank when the tank is no more than 95% full.”
Model O, Pressure Regulating Valves - Installed in the supply line to boiler fuel metering valves. The valve senses down stream pressure to maintain a constant supply pressure to the fuel metering valves.
Model R, Relief Valves - Designed to relieve excess pressure in lines containing any grade of fuel oil. It is also suitable for use with water and air.
Sidewalk Fill Box - Designed to be set flush in a concrete sidewalk and provide easy access to fill and/or sounding line terminals, valves, meters and similar equipment which is installed below grade.
Model 3, Sidewalk Spill Container With Overfill Alarm and Digital Tank Volume Display - The Model 3 Sidewalk Spill Container flush-mounts into any horizontal sidewalk or pavement and is held in place with four concrete anchor bolts.
Model 125, Simplex Oil Strainers - Designed for applications where easy maintenance and large capacity straining are required. Service time is minimal because the cover is secured with quick opening, non-yoke type knobs.
Model 900, Single Poppet Foot Valve - Installed at the end of suction lines at the bottom of fuel oil tanks to keep the suction line to the pump set primed by preventing the flow of oil back into the tank when the pumps are not in operation. Preferred Utilities' industrial factory is located in Danbury, CT (Connecticut).
Model TG-MH-18, Storage Tank Monitor Access Manhole - Designed to set flush on a concrete pad at grade and provide access as required to equipment installed on an underground tank, such as tank gauging and leak detection equipment.
Tank Selector Valves, Threaded And Flanged Connections - Consists of a precision ground tapered plug which rotates 90 degrees within a precision machined cast iron body.
Tank Vent Brick - Designed as a terminal for vent lines from storage tanks when the line is run inside the building walls. Approved by the New York City Board of Standars and Appeals.
Model W, Watertight Flush Fill Cap - Assembly consists of a rust-resistant, galvanized cast iron body, with a gasket sealed solid bronze cover for a waterproof seal. A cast iron turning wrench is included.Fill caps are available in 2", 3", and 4" NPT. Approved by The New York City Board of Standards and Appeals
Model FF, Watertight Locking Fill Cap - Assembly consists of a solid cast iron body with malleable iron hasp. The brass cover is gasketed to provide a waterproof seal. The body threads directly on to the line while the cap threads onto the body.